Skip to content
info@bushingbearings.com +86 15999653684

Insert Bearings & Housed Units · ISO 3228 / JIS B 1559

25 mm Bore UCP200 Series Pillow Block Units Dimensions

The dimensional row to ISO 3228 / JIS B 1559 for this bore, with the mounting and lubrication notes for the type.

25 mm bore UCP200 Series Pillow Block Units to ISO 3228 / JIS B 1559 (UCP205): width B 140 mm.

Bore d
25 mm
Width B
140 mm

Boundary dimensions are fixed by the standard and are the same from every manufacturer. Load ratings and limiting speeds are manufacturer-declared values computed to the method of ISO 281, and internal clearance is measured before mounting.

Agricultural machinery bearing — UCP200 Series Pillow Block Units in service

UCP200 Series Pillow Block Units are tabulated at a 25 mm bore: the row from the product table, the recommended shaft and housing tolerances under a rotating inner ring, the abutment the corner radius permits, and the notes that decide whether this bearing reaches its calculated life.

25 mm Bore Dimensional Row (ISO 3228 / JIS B 1559)

DesignationShaft bore d (mm)Height to shaft centre H (mm)Bolt hole centres J (mm)Overall length L (mm)Housing material
UCP2052536.5105140Grey cast iron

What a UCP200 Series Pillow Block Units Does

A housed unit is a complete mounted bearing: an insert bearing with a wide inner ring, its housing, its seals and its grease, ready to bolt down. It clamps onto a commercial-tolerance shaft with setscrews or an eccentric collar, and the insert's spherical outer surface takes up the misalignment between two bolted feet — so a conveyor or a fan can be built without machining a bearing seat at all.

Primarily radial load, with a limited axial capacity in both directions. Treat the axial figure as a secondary rating, not as a thrust rating.

Speed at 25 mm Bore

No limiting speed is tabulated for this product. Where speed matters, the figure to work to is the one the bearing supplier states for the exact design, cage and lubricant supplied — not a family value.

Mounting a 25 mm Bore UCP200 Series Pillow Block Units

The insert bearing clamps onto the shaft with setscrews or an eccentric locking collar; the shaft needs only a commercial tolerance (h6 to h9), not a ground bearing seat. That is what makes a housed unit quick to install, and it is also its limitation: a setscrew grip transmits far less torque than an interference fit and can fret or creep on the shaft under reversing or heavily shocked load, where a keyed or interference-fitted arrangement should be used instead.

Lubrication & Relubrication

The unit is supplied greased and sealed, ready to run. Most housed units also carry a grease nipple: relubricate through it at the interval the duty calls for, with the shaft turning, until fresh grease shows at the seal. Speed, temperature and a wet or dusty environment all shorten the interval, and a unit run continuously in a washdown line needs a purge schedule rather than an annual one.

Sealed-for-life versions carry their whole service life of grease inside the seals and cannot be relubricated. That is the right choice where the bearing is inaccessible and the duty is mild; it is the wrong one where the temperature is high, the environment is wet, or the required life is longer than the grease life — and the grease, not the steel, is what ends it.

Failure Modes and What They Look Like

  • Subsurface fatigue (spalling) — a flake of raceway lifts out and the bearing gets noisy and rough. This is the failure the L10 life calculation predicts — if it arrives near the calculated life the bearing did its job, and if it arrives early the load, the fit or the lubrication was not what the calculation assumed.
  • Inadequate lubrication — a polished, then discoloured, then torn raceway, running hot with a darkened grease. It is the most common cause of early failure by a wide margin, and the interval, not the grease, is usually what was wrong.
  • Contamination — dents in the raceway with raised edges, then premature spalling from those dents. Wear particles, casting sand and washdown water all do it; sealing and filtration are what prevent it.
  • False brinelling and fretting — evenly spaced dull marks at ball or roller pitch, produced by vibration while the shaft is stationary — a machine that travels on a truck, or a standby pump beside a running one. It is not caused by overload and cannot be cured by fitting a bigger bearing.
  • Shaft fretting under the setscrews — a polished, reddish band on the shaft under the inner ring and a unit that loosens repeatedly. The setscrew grip was asked to hold against reversing torque that needs a key or an interference fit.
  • Seal failure — grease escaping, then water and dirt getting in. A contact seal is a wearing part with a temperature limit of its own, and a washdown at 80 °C will get past a standard nitrile lip long before the bearing itself is in trouble.

Where NOT to Use a UCP200 Series Pillow Block Units

  • Do not use a setscrew insert bearing under reversing or heavily shocked torque. The grip is a friction one; it frets and creeps, and the shaft ends up polished and undersized. Use a keyed shaft, an adapter sleeve unit, or a plummer block.
  • Do not use the unit's self-alignment as a substitute for parallel feet. It takes up static misalignment between two seats; it does not survive a soft foot or a base that flexes under load.
  • Do not specify a standard cast iron unit for a washdown line. The housing corrodes, the standard seals let water in, and the correct answer is a stainless or composite unit with the right seal package.
  • Do not treat a sealed bearing as sealed for life in a wet or hot environment. A contact seal has a temperature and a pressure limit of its own, and once it is past them the grease leaves and the water arrives.

Stepping Up or Down from 25 mm

Within the same series, the next bore up in this series is 30 mm and the next bore down is 20 mm. Changing bore changes the shaft, so it is the last thing to change: when the calculated life at 25 mm is short, the first move is to a heavier diameter series at the SAME bore — the 6300 envelope instead of the 6200, for instance — which raises the rating without touching the shaft. The second is to change type: a roller bearing carries far more radial load than a ball bearing of the same envelope.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the designation snaps the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.
Our facility

The numbers come off our own machines

Every ring is gauged for bore and outside diameter, every assembly for radial internal clearance to ISO 5753-1, and every finished bearing for vibration. That is why the values on this page are quotable rather than indicative.

Bearing production line, wide view
Ring inspection station
Bearing assembly and clearance setting
Finished bearings staged for packing

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ISO 3228 / JIS B 1559)

DesignationShaft bore d (mm)Height to shaft centre H (mm)Bolt hole centres J (mm)Overall length L (mm)Housing material
UCP2011230.295127Grey cast iron
UCP2021530.295127Grey cast iron
UCP2031730.295127Grey cast iron
UCP2042033.395127Grey cast iron
UCP2052536.5105140Grey cast iron
UCP2063042.9121165Grey cast iron
UCP2073547.6127167Grey cast iron
UCP2084049.2137184Grey cast iron
UCP2094554146190Grey cast iron
UCP2105057.2159206Grey cast iron
UCP2115563.5171219Grey cast iron
UCP2126069.9184236Grey cast iron
UCP2136576.2197254Grey cast iron
UCP2147079.4210266Grey cast iron
UCP2157582.6217275Grey cast iron
UCP2168088.9232292Grey cast iron
UCP2178595.3248310Grey cast iron
UCP21890101.6260328Grey cast iron

Video: 25 mm Bore UCP200 Series Pillow Block Units Dimensions

Installation of ASAHI Insert Bearing Unit with an Adapter - Asahi Seiko Co., Ltd.

Third-party video, selected automatically for this topic. It is not produced by Bushing Bearings and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

When should I NOT use a UCP200 Series Pillow Block Units?

Do not use a setscrew insert bearing under reversing or heavily shocked torque. The grip is a friction one; it frets and creeps, and the shaft ends up polished and undersized. Use a keyed shaft, an adapter sleeve unit, or a plummer block. Do not use the unit's self-alignment as a substitute for parallel feet. It takes up static misalignment between two seats; it does not survive a soft foot or a base that flexes under load.

What if the calculated life at 25 mm is too short?

Change the series before you change the shaft. A heavier diameter series at the same 25 mm bore raises the rating without any change to the shaft or the assembly; a different bearing type at the same envelope changes it more. Going up to the next bore, 30 mm, means a new shaft.

Does a 2RS seal change the speed limit?

Yes. A 2RS contact seal rubs on the inner ring, and that friction generates heat, so the sealed version of a bearing runs slower than the open or shielded one — commonly around half the tabulated limiting speed. A ZZ shield does not touch the ring and costs very little speed, but it also keeps far less dirt out. The seal is also a temperature limit in its own right: nitrile gives out near +110 °C long before the rings do.

How is a 25 mm bore UCP200 Series Pillow Block Units mounted?

The insert bearing clamps onto the shaft with setscrews or an eccentric locking collar; the shaft needs only a commercial tolerance (h6 to h9), not a ground bearing seat. That is what makes a housed unit quick to install, and it is also its limitation: a setscrew grip transmits far less torque than an interference fit and can fret or creep on the shaft under reversing or heavily shocked load, where a keyed or interference-fitted arrangement should be used instead.

How do I request a quotation?

Use the technical drawing on this page to pick the exact configuration, then submit it with the quote form. We respond within one business day.