Skip to content
info@bushingbearings.com +86 15999653684

Angular Contact Ball Bearings · ISO 15 / DIN 628-1 / GB/T 292 · Application guide

What Are 7000AC Series Angular Contact Ball Bearings Used For?

Typical applications, the industries that specify 7000ac series angular contact ball bearings in 10 mm to 100 mm bore, how to state the designation, clearance, sealing, cage and fit on an order, and where a different bearing type is the right answer.

7000AC Series Angular Contact Ball Bearings are used for carrying combined radial and axial load where the axial component acts in one direction, mounted against a second bearing that takes it in the other. Boundary dimensions are to ISO 15 / DIN 628-1 / GB/T 292, and selection is driven by the contact angle, which sets how the capacity is split between radial and axial, and by the arrangement and preload of the pair the bearing works in.

Primary duty
Carrying combined radial and axial load where the axial component acts in one direction, mounted against a second bearing that takes it in the other
Load direction
Combined radial and axial; axial in one direction only for a single row
Bore range
10 mm to 100 mm
Boundary dimensions
ISO 15 / DIN 628-1 / GB/T 292
Category
Angular Contact Ball Bearings

Application notes are general engineering guidance. Basic load ratings, limiting speeds and permissible misalignment vary between manufacturers for the same designation — verify them against the catalog of the bearing actually being supplied, and against your own bearing life calculation.

Woodworking planer cutterhead bearing — a typical application for 7000AC Series Angular Contact Ball Bearings
A typical service position for 7000AC Series Angular Contact Ball Bearings.

The duty of 7000AC Series Angular Contact Ball Bearings is carrying combined radial and axial load where the axial component acts in one direction, mounted against a second bearing that takes it in the other. The line joining the ball contacts runs at an angle to the radial plane, so load is transmitted diagonally through the bearing: a single row can only push axially one way, and it must be opposed by something that pushes back. The sections that follow cover the sectors that specify them, how to state the designation, clearance, sealing, cage and fit on an order, how to mount them, and the known limits of the type. Dimensions are to ISO 15 / DIN 628-1 / GB/T 292. This series is catalogued from 10 mm to 100 mm bore; the full table of boundary dimensions is further down the page.

Typical Applications for 7000AC Series Angular Contact Ball Bearings

The machine positions and sectors where this type is specified:

  • Vertical shafts: positions where the shaft weight itself is a permanent axial load with the radial load small.
  • Compressors and blowers: axially loaded rotor shafts running at speed, arranged back-to-back for moment stiffness.
  • Maintenance and repair (MRO): replacing a failed bearing where the original designation, clearance group and sealing have to be matched exactly.
  • OEM machine building: designed-in shaft support on new equipment, specified from the load, speed and envelope at the design stage.
  • Machine tool spindles: matched sets carrying the cutting thrust and holding the spindle stiff, where preload sets the running accuracy and 15° angles are chosen for speed.

How to Specify 7000AC Series Angular Contact Ball Bearings for Your Application

  • Bore: Start from the bore the shaft or housing gives you — this series is catalogued from 10 mm to 100 mm — then check the outer diameter and width against the space available. The boundary dimensions are fixed by the standard, so they are the same from any manufacturer; the load ratings and limiting speeds are not, and belong to the specific bearing being supplied.
  • Opposing bearing: Name the bearing this one works against on the order or the drawing. A single row is half of an arrangement, and the axial setting belongs to the pair, not to either bearing.
  • Contact angle: The contact angle is the whole decision. A 15° bearing (7000 C) has the lowest axial capacity and the highest permissible speed; a 40° bearing (7000 B) takes far more axial load and runs slower. 25° and 30° sit between them. State the angle explicitly — it is a suffix, not an option, and two bearings with the same boundary dimensions and different angles are different bearings.
  • Arrangement: Single rows are used in pairs and the pairing is part of the order. Back-to-back (DB) sets the load lines apart and gives a rigid, moment-carrying pair; face-to-face (DF) is more tolerant of misalignment and less stiff; tandem (DT) doubles capacity in one direction only and still needs opposing. Double row and four-point contact designs take both directions in a single bearing.
  • Designation and suffixes: State the complete designation including every suffix. The base number gives the type and the boundary dimensions; the suffixes carry the sealing, the cage, the clearance group, the tolerance class and any special execution — and two bearings whose base numbers match but whose suffixes differ are not interchangeable.
  • Preload class: This type is specified by preload rather than by an internal clearance group, because the axial setting is made when the bearings are clamped together on assembly. State the preload class (light, medium, heavy) on the order, and state the arrangement it applies to — the preload belongs to the set, not to one bearing.
  • Seal or shield: State open, shielded (ZZ, 2Z) or sealed (2RS, 2RZ). A shield is non-contacting: it excludes coarse contamination and costs nothing in speed. A contact seal excludes fine dust and water and retains grease, but it rubs — it adds drag, raises the running temperature and lowers the permissible speed. Sealed bearings are also greased for life and cannot be relubricated.
  • Cage material: State the cage. Pressed steel is the default and suits most duties; machined brass takes shock, high temperature and poor lubrication better and is used in large and heavily loaded bearings; polyamide is quiet, light and low-friction but has a temperature limit of about 120 °C and is attacked by aged oil. The cage is not a detail — it is the component that most often sets the real temperature limit of the bearing.
  • Shaft and housing fit: Specify the seat tolerances, not just the bearing. The rule is that the ring which rotates relative to the load direction takes the interference fit: for a rotating inner ring under normal radial load the shaft seat is typically k5 or k6 with the housing bore H7, and where the outer ring rotates the interference moves to the housing (N7 or P7) with a clearance fit (g6) on the shaft. Heavier loads and hollow shafts move the fits tighter. A correctly chosen bearing in the wrong fit fails anyway — too loose and the ring creeps and frets its seat, too tight and the interference consumes the internal clearance and the bearing runs preloaded.
  • Standard: Boundary dimensions are to ISO 15 / DIN 628-1 / GB/T 292. Quoting the standard on the order guarantees the mounting dimensions are interchangeable between suppliers — it does not standardize load ratings, limiting speeds or internal design, which remain manufacturer-specific.

Mounting & Assembly Practice

  • Mount single rows in opposition and clamp both rings axially. A single angular contact bearing tightened on the shaft with the outer ring free is not located at all.
  • A matched set is supplied ground so that clamping the rings together produces a defined preload. Keep the set together, keep the marks aligned, and do not substitute one bearing of a pair.
  • Set the preload by clamping to the shoulders and locknut, not by force on a press. Rotate the shaft several turns while tightening so the balls take up their contact position before the final measurement.
  • Do not swap the fit direction: the ring that is loaded in the axial direction takes the interference, and the opposing ring must remain free enough to be drawn up when the set is clamped.

Common Selection Mistakes with 7000AC Series Angular Contact Ball Bearings

  • Fitting one single-row angular contact bearing on its own and expecting the shaft to be located. It carries axial load one way and gives no location at all in the other; the shaft simply moves until something else stops it.
  • Choosing a 40° bearing for its axial rating on a spindle running near the speed limit, when the whole reason a spindle uses 15° bearings is that the shallow angle lowers the centrifugal load on the ball and the heat it generates.
  • Confusing DB and DF. They are not interchangeable: DB carries a tilting moment and DF barely does, and a DF pair fitted where a DB pair was designed leaves the shaft flexible enough to chatter.
  • Sizing this bearing from the boundary dimensions alone. Load ratings and limiting speeds are manufacturer-specific for this series and are deliberately not published here — take them from the catalog of the bearing actually being supplied and calculate the life against them.

Where 7000AC Series Angular Contact Ball Bearings Are Not the Right Choice

  • A single row on its own gives no axial location in the second direction and cannot be used alone.
  • Never on its own for a reversing axial load. A single row takes thrust in one direction only; reversing load unseats the contact and the balls skid across the raceway.
  • Not where the axial load direction is unknown at design time — a double row or four-point contact bearing carries both directions in one part.
  • Contact seals do not belong on precision spindle bearings: their drag is precisely the loss that a preloaded spindle bearing is specified to avoid.
Pump shaft bearing — a typical application for 7000AC Series Angular Contact Ball Bearings
Another position where 7000AC Series Angular Contact Ball Bearings are specified.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the designation snaps the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

Specification
Business Information
Our facility

Built for the duty, not just catalogued for it

Clearance group, cage material and seal type are chosen on our own assembly line to match the duty described above — a bearing specified correctly and built to the wrong clearance runs hot exactly as fast as one specified wrongly.

Bearing production line, wide view
Ring inspection station
Bearing assembly and clearance setting
Finished bearings staged for packing

Dimensions & Specifications (ISO 15 / DIN 628-1 / GB/T 292)

DesignationBore d (mm)Outer diameter D (mm)Width B (mm)Chamfer r min (mm)Contact angle a (deg)
7000AC102680.325
7001AC122880.325
7002AC153290.325
7003AC1735100.325
7004AC2042120.625
7005AC2547120.625
7006AC305513125
7007AC356214125
7008AC406815125
7009AC457516125
7010AC508016125
7011AC5590181.125
7012AC6095181.125
7013AC65100181.125
7014AC70110201.125
7015AC75115201.125
7016AC80125221.125
7017AC85130221.125
7018AC90140241.525
7019AC95145241.525
7020AC100150241.525

Video: What Are 7000AC Series Angular Contact Ball Bearings Used For? in use

HYDRAULIC PRESS VS BALL BEARINGS! Which will EXPLODE first?

Third-party video, selected automatically for this topic. It is not produced by Bushing Bearings and is not a specification source — use the tables on this page for dimensional data.

Inside the plant

Manufactured in our own plant

This bearing is forged, hardened, ground, superfinished and clearance-set in-house. The stages below are where its tolerance class, its internal clearance and its noise grade are actually decided.

  1. Bearing ring blanks coming off the forging press
    01

    Forging & turning

    GCr15 bar and tube is cut, heated and forged into ring blanks, then turned to leave a uniform grinding allowance. Forging rather than machining from solid keeps the grain flow following the raceway, which is the surface that eventually fails.

    Blank dimensions and grinding stock checked at set-up and per shift.

  2. Bearing rings entering a continuous hardening furnace
    02

    Heat treatment

    Through-hardening brings GCr15 / 100Cr6 to 58–64 HRC; carburizing case-hardens 20CrMnTi where the section is heavy or the load is shock. Rings are then stabilized so they hold size in service rather than growing in the housing.

    Core and surface hardness per lot; retained austenite and dimensional stability to the ordered temperature class.

  3. Raceway grinding machine finishing a bearing inner ring
    03

    Raceway grinding

    Faces, bore, outer diameter and raceway are ground in sequence on separate machines. This is where the tolerance class is created: P0, P6, P5 or P4 is a grinding outcome, not a sorting outcome.

    Bore and outer diameter deviation, raceway roundness and face runout measured to ISO 492 on every setup.

  4. Superfinishing stones acting on a ground raceway
    04

    Honing & superfinishing

    The ground raceway is honed to remove the grinding lay and bring surface roughness down to a fraction of a micrometre. Raceway finish is what decides whether a lubricant film forms, and therefore what decides bearing life far more than the load rating alone.

    Surface roughness Ra and waviness measured per lot.

Frequently Asked Questions

Which contact angle should I choose?

Choose the angle from the ratio of axial to radial load and from the speed. A 15° bearing carries the least thrust and the most speed, and is the machine tool spindle default. A 40° bearing carries the most thrust and runs slowest, and suits worm gearboxes and pump thrust positions. Intermediate 25° and 30° angles cover the middle of that range.

What does DB, DF or DT mean on the order?

They describe how two bearings are arranged. DB is back-to-back: the load lines diverge, giving the widest effective bearing spread and the best resistance to tilting moments. DF is face-to-face: the load lines converge, so the pair is less stiff but more forgiving of misalignment. DT is tandem: both rows face the same way and share one direction of axial load between them.

How do I choose the right size of 7000AC Series Angular Contact Ball Bearings?

Start from the bore the shaft or housing gives you — this series is catalogued from 10 mm to 100 mm — then check the outer diameter and the width against the space available, and confirm the calculated life against the load and speed. The full table of boundary dimensions is on this page.

What has to be stated when ordering 7000AC Series Angular Contact Ball Bearings?

The complete designation with every suffix, the internal clearance group or preload class, the seal or shield type, and the cage material — plus the shaft and housing seat tolerances on the drawing. The bearing and the fit are one specification: a correctly chosen bearing in the wrong fit either creeps on its seat or runs preloaded.

Can I get a quote for 7000AC Series Angular Contact Ball Bearings in the size and specification I need?

Yes. Use the technical drawing and quote form on this page to set the size and options, then send the exact configuration — designation, clearance, sealing and cage — to our team for pricing and lead time.