17 mm Bore UCFL200 Series Two-Bolt Flange Units Dimensions

The dimensional row to ISO 3228 / JIS B 1559 for this bore, with the mounting and lubrication notes for the type.

17 mm bore UCFL200 Series Two-Bolt Flange Units are dimensioned to ISO 3228 / JIS B 1559. The boundary dimensions, the recommended fits and the clearance for this bore are tabulated below.

Bore d
17 mm

Boundary dimensions are fixed by the standard and are the same from every manufacturer. Load ratings and limiting speeds are manufacturer-declared values computed to the method of ISO 281, and internal clearance is measured before mounting.

Conveyor roller bearing — UCFL200 Series Two-Bolt Flange Units in service

Dimensional and installation data for the 17 mm bore size of UCFL200 Series Two-Bolt Flange Units, dimensioned to ISO 3228 / JIS B 1559. Selection is by bore diameter — the bearing designation is what the shaft is machined to — so the figures below start with the boundary dimensions and go on to the fits, the clearance and the mounting method that make them work.

17 mm Bore Dimensional Row (ISO 3228 / JIS B 1559)

DesignationShaft bore d (mm)Insert bearingHousing material
UCFL20317UC203Grey cast iron

What a UCFL200 Series Two-Bolt Flange Units Does

A housed unit is a complete mounted bearing: an insert bearing with a wide inner ring, its housing, its seals and its grease, ready to bolt down. It clamps onto a commercial-tolerance shaft with setscrews or an eccentric collar, and the insert's spherical outer surface takes up the misalignment between two bolted feet — so a conveyor or a fan can be built without machining a bearing seat at all.

Primarily radial load, with a limited axial capacity in both directions. Treat the axial figure as a secondary rating, not as a thrust rating.

Speed at 17 mm Bore

No limiting speed is tabulated for this product. Where speed matters, the figure to work to is the one the bearing supplier states for the exact design, cage and lubricant supplied — not a family value.

Mounting a 17 mm Bore UCFL200 Series Two-Bolt Flange Units

The insert bearing clamps onto the shaft with setscrews or an eccentric locking collar; the shaft needs only a commercial tolerance (h6 to h9), not a ground bearing seat. That is what makes a housed unit quick to install, and it is also its limitation: a setscrew grip transmits far less torque than an interference fit and can fret or creep on the shaft under reversing or heavily shocked load, where a keyed or interference-fitted arrangement should be used instead.

Where a 17 mm Bore UCFL200 Series Two-Bolt Flange Units Is Used

At a 17 mm bore, ucfl200 series two-bolt flange units are typically found in electric motors, pumps, gearbox layshafts, machine tool auxiliaries, agricultural machinery and general industrial drives — the volume range of the whole bearing industry.

Failure Modes and What They Look Like

  • Subsurface fatigue (spalling) — a flake of raceway lifts out and the bearing gets noisy and rough. This is the failure the L10 life calculation predicts — if it arrives near the calculated life the bearing did its job, and if it arrives early the load, the fit or the lubrication was not what the calculation assumed.
  • Inadequate lubrication — a polished, then discoloured, then torn raceway, running hot with a darkened grease. It is the most common cause of early failure by a wide margin, and the interval, not the grease, is usually what was wrong.
  • Contamination — dents in the raceway with raised edges, then premature spalling from those dents. Wear particles, casting sand and washdown water all do it; sealing and filtration are what prevent it.
  • False brinelling and fretting — evenly spaced dull marks at ball or roller pitch, produced by vibration while the shaft is stationary — a machine that travels on a truck, or a standby pump beside a running one. It is not caused by overload and cannot be cured by fitting a bigger bearing.
  • Shaft fretting under the setscrews — a polished, reddish band on the shaft under the inner ring and a unit that loosens repeatedly. The setscrew grip was asked to hold against reversing torque that needs a key or an interference fit.
  • Seal failure — grease escaping, then water and dirt getting in. A contact seal is a wearing part with a temperature limit of its own, and a washdown at 80 °C will get past a standard nitrile lip long before the bearing itself is in trouble.

Where NOT to Use a UCFL200 Series Two-Bolt Flange Units

  • Do not use a setscrew insert bearing under reversing or heavily shocked torque. The grip is a friction one; it frets and creeps, and the shaft ends up polished and undersized. Use a keyed shaft, an adapter sleeve unit, or a plummer block.
  • Do not use the unit's self-alignment as a substitute for parallel feet. It takes up static misalignment between two seats; it does not survive a soft foot or a base that flexes under load.
  • Do not specify a standard cast iron unit for a washdown line. The housing corrodes, the standard seals let water in, and the correct answer is a stainless or composite unit with the right seal package.
  • Do not treat a sealed bearing as sealed for life in a wet or hot environment. A contact seal has a temperature and a pressure limit of its own, and once it is past them the grease leaves and the water arrives.

Stepping Up or Down from 17 mm

Within the same series, the next bore up in this series is 20 mm and the next bore down is 15 mm. Changing bore changes the shaft, so it is the last thing to change: when the calculated life at 17 mm is short, the first move is to a heavier diameter series at the SAME bore — the 6300 envelope instead of the 6200, for instance — which raises the rating without touching the shaft. The second is to change type: a roller bearing carries far more radial load than a ball bearing of the same envelope.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the designation snaps the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.
Our facility

Held in production, not just on paper

The tolerances above are decided on the grinding and superfinishing lines in our own plant, and gauged on every ring rather than on a sample. A dimension is only worth quoting if it survives the process that produces it.

Bearing production line, wide view
Ring inspection station
Bearing assembly and clearance setting
Finished bearings staged for packing

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ISO 3228 / JIS B 1559)

DesignationShaft bore d (mm)Insert bearingHousing material
UCFL20112UC201Grey cast iron
UCFL20215UC202Grey cast iron
UCFL20317UC203Grey cast iron
UCFL20420UC204Grey cast iron
UCFL20525UC205Grey cast iron
UCFL20630UC206Grey cast iron
UCFL20735UC207Grey cast iron
UCFL20840UC208Grey cast iron
UCFL20945UC209Grey cast iron
UCFL21050UC210Grey cast iron
UCFL21155UC211Grey cast iron
UCFL21260UC212Grey cast iron
UCFL21365UC213Grey cast iron
UCFL21470UC214Grey cast iron
UCFL21575UC215Grey cast iron
UCFL21680UC216Grey cast iron
UCFL21785UC217Grey cast iron
UCFL21890UC218Grey cast iron

Video: 17 mm Bore UCFL200 Series Two-Bolt Flange Units Dimensions

Third-party video, selected automatically for this topic. It is not produced by Bushing Bearings and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What if the calculated life at 17 mm is too short?

Change the series before you change the shaft. A heavier diameter series at the same 17 mm bore raises the rating without any change to the shaft or the assembly; a different bearing type at the same envelope changes it more. Going up to the next bore, 20 mm, means a new shaft.

Does a 2RS seal change the speed limit?

Yes. A 2RS contact seal rubs on the inner ring, and that friction generates heat, so the sealed version of a bearing runs slower than the open or shielded one — commonly around half the tabulated limiting speed. A ZZ shield does not touch the ring and costs very little speed, but it also keeps far less dirt out. The seal is also a temperature limit in its own right: nitrile gives out near +110 °C long before the rings do.

How is a 17 mm bore UCFL200 Series Two-Bolt Flange Units mounted?

The insert bearing clamps onto the shaft with setscrews or an eccentric locking collar; the shaft needs only a commercial tolerance (h6 to h9), not a ground bearing seat. That is what makes a housed unit quick to install, and it is also its limitation: a setscrew grip transmits far less torque than an interference fit and can fret or creep on the shaft under reversing or heavily shocked load, where a keyed or interference-fitted arrangement should be used instead.

Which loads does a UCFL200 Series Two-Bolt Flange Units take?

Primarily radial load, with a limited axial capacity in both directions. Treat the axial figure as a secondary rating, not as a thrust rating.

How do I request a quotation?

Use the technical drawing on this page to pick the exact configuration, then submit it with the quote form. We respond within one business day.