Skip to content
info@bushingbearings.com +86 15999653684

Ball Bearings · ISO 15 / DIN 625-1 / GB/T 276

75 mm Bore 6000-ZZ Series Shielded Ball Bearings Dimensions

The dimensional row to ISO 15 / DIN 625-1 / GB/T 276 for this bore, with the recommended shaft and housing fit, the CN and C3 internal clearance range and the basic load ratings.

75 mm bore 6000-ZZ Series Shielded Ball Bearings to ISO 15 / DIN 625-1 / GB/T 276 (6015-ZZ): outside diameter D 115 mm, width B 20 mm, limiting corner radius r min 1.1 mm, basic dynamic load rating Cr 41.6 kN. On a solid steel shaft the seat is k5 or k6 under a normal rotating-inner-ring load, j6 under light load, in a cast iron or steel housing bored H7 where the outer ring must be free to move axially. Radial internal clearance before mounting is 10-30 µm in CN and 25-51 µm in C3 per ISO 5753-1; the interference fit and any temperature difference across the bearing consume part of it. The chamfer dimension r min is 1.1 mm, so the fillet in the shaft or housing corner must not exceed 1.1 mm and the abutment shoulder has to stand clear of the ring corner to bear on the ring face.

Bore d
75 mm
Outside diameter D
115 mm
Width B
20 mm
Chamfer r min
1.1 mm
Basic dynamic load rating Cr
41.6 kN
Shaft seat, rotating inner ring
k5 or k6 normal load

Boundary dimensions are fixed by the standard and are the same from every manufacturer. Load ratings and limiting speeds are manufacturer-declared values computed to the method of ISO 281, and internal clearance is measured before mounting.

Electric motor bearing — 6000-ZZ Series Shielded Ball Bearings in service

The 75 mm bore of the 6000-ZZ Series Shielded Ball Bearings is the 6015-ZZ: 75 mm bore, 115 mm outside diameter, 20 mm wide. This page gives the dimensional row from the table, the shaft and housing fits that suit it, the internal clearance to expect and the mounting, lubrication and failure notes that go with the type.

75 mm Bore Dimensional Row (ISO 15 / DIN 625-1 / GB/T 276)

DesignationBore d (mm)Outer diameter D (mm)Width B (mm)Chamfer r min (mm)Shield typeOperating temperature range (u00b0C)Basic dynamic load rating Cr (kN)Basic static load rating C0r (kN)
6015-ZZ75115201.1Pressed steel shield, both sides-30 to +12041.633.5

What a 6000-ZZ Series Shielded Ball Bearings Does

A single row of balls runs in deep, uninterrupted grooves in both rings. That geometry gives low friction, quiet running and a useful axial capacity in both directions alongside the radial load, which is why the deep groove ball bearing is the default choice for electric motors, pumps, fans, gearbox layshafts and small machinery wherever the load is moderate and the shaft is stiff.

Primarily radial load, with a real but secondary axial capacity in both directions taken by the groove shoulders. Combined loading is normal service for this type; pure heavy thrust is not, and a bearing asked to work as a thrust bearing runs its contact ellipse over the groove edge.

Load Ratings at 75 mm Bore

Basic dynamic load rating Cr41.6 kN
Basic static load rating C0r33.5 kN

The dynamic rating Cr is the load at which the bearing reaches one million revolutions of basic rating life with 90% reliability, and it is the number that goes into L10 = (C/P)^p — p being 3 for ball bearings and 10/3 for roller bearings. The static rating C0r is the load that produces a permanent deformation of 0.0001 of the rolling element diameter at the most heavily loaded contact, and it is the figure that matters for a bearing that is loaded while it is standing still, shock loaded, or oscillating through a small angle.

Ratings are not fixed by standard. ISO 281 fixes the METHOD; the values are declared by the manufacturer from the internal geometry, so figures for the same designation differ by a few percent between makers. Use one maker's rating with that maker's bearing.

Speed at 75 mm Bore

No limiting speed is tabulated for this product. Where speed matters, the figure to work to is the one the bearing supplier states for the exact design, cage and lubricant supplied — not a family value.

Shaft & Housing Fit for a 75 mm Seat

With the inner ring rotating under a load whose direction is fixed, the inner ring sees a circumferential load and must be an interference fit, or it will creep on the shaft and fret it. The outer ring sees a point load and takes a transition or clearance fit so that it can shift slowly and spread the wear — and so that one of the two bearings on the shaft is free to take up axial expansion.

Shaft, light load (P ≤ 0.06 C)j6
Shaft, normal load (P = 0.06–0.12 C)k5 or k6
Shaft, heavy or shock load (P > 0.12 C)n6
Housing — Axial displacement of the outer ring requiredH7
Housing — Normal load, outer ring may still shiftJ7
Housing — Normal to heavy load, quiet running, outer ring not displaceableK7

ISO 286-2 tolerance grades, applied per the conventional bearing seat recommendations of ISO 1132-2 and DIN 5425-1, for a SOLID STEEL shaft in a cast iron or steel housing. A hollow shaft, a thin-walled housing or a light alloy housing needs a tighter fit than these, because the seat itself deflects.

Radial Internal Clearance at 75 mm Bore

Radial internal clearance is the total distance one ring can be moved relative to the other, across the bearing, before it is mounted. It is not a tolerance and not a quality grade: it is a quantity that gets USED UP on installation. An interference fit on the shaft expands the inner ring; a tight housing fit compresses the outer ring; and a shaft that runs hotter than its housing grows more than the housing does. All three subtract from the clearance the bearing was made with. C3 exists for that reason. Specify it when the shaft fit is heavier than normal, when the inner ring will run 10 °C or more above the outer, when a hollow or heated shaft is involved, or when the bearing sits on an adapter sleeve that is driven up hard. Specify CN — normal, and usually left out of the designation entirely — for the ordinary case of a moderate fit on a shaft close to housing temperature. The failure this prevents is specific and quick: fit a CN bearing with a heavy interference on a shaft that then runs hot, and the residual clearance goes negative. The bearing is now preloaded by its own installation, the rolling elements are squeezed, friction and temperature rise together, and the temperature rise tightens the fit further. It runs hot, then it runs blue, and the raceways spall long before the calculated life.

CN (normal), bore over 65 up to 80 mm10–30 µm
C3 (greater than normal)25–51 µm
C2 (smaller than normal)1–15 µm
C4 (greater than C3)46–71 µm

Pre-mounting values per ISO 5753-1 / GB/T 4604 for single row deep groove ball bearings with a cylindrical bore. Other bearing types have their own tables in the same standard with different values.

Abutment Shoulder & Fillet Radius for 75 mm

The chamfer dimension r min for this size is 1.1 mm. That figure is a limit on YOUR machining, not just on the bearing: the fillet radius in the corner of the shaft or the housing must be smaller than the bearing's corner radius, or the ring seats on the fillet instead of on the shoulder face and is loaded on its corner.

Chamfer dimension r min (from the table)1.1 mm
Maximum fillet radius on the shaft or housing1.1 mm
Shaft shoulder must exceed77.2 mm diameter
Housing shoulder bore must be under112.8 mm diameter

The two shoulder figures are the geometric floor and ceiling: a shoulder outside them fouls the corner radius instead of bearing on the ring face. The practical values sit inside them — the shoulder must contact the ring face over a useful area without touching the seal, the cage or the opposite ring, and it must still leave room for a puller when the bearing is dismounted. Take the working da and Da from the abutment table for the bearing; the ring shoulder height they are built on is not a boundary dimension and is not in this table.

Mounting a 75 mm Bore 6000-ZZ Series Shielded Ball Bearings

The ring that carries the rotating load takes an interference fit; the ring under a stationary point load takes a transition or clearance fit so that it can creep slowly and spread the wear, and so that one ring is free to take up axial expansion. With a rotating shaft under a fixed load direction, that means an interference fit on the shaft and a looser fit in the housing. Press only against the ring being fitted — force driven through the rolling elements leaves brinell marks in the raceway before the bearing has run a revolution.

At a 75 mm bore the interference is small enough that a cold press or a light hydraulic press is normally enough; heating the bearing in an induction heater or an oil bath to 80–100 °C above the shaft is the alternative, and never above 120 °C for a standard-stabilized bearing. Keep the heated bearing pressed against the shoulder while it cools, because it shrinks axially as well as radially.

Lubrication & Relubrication

Grease is the normal lubricant for this type: it stays where it is put, helps to keep contamination out, and needs no circulation system. Fill roughly 30% to 50% of the free space in the bearing arrangement — a bearing packed full runs hot, because the excess grease is churned rather than used. The relubrication interval is not a fixed figure; it falls with speed, with temperature and with load, and it halves for roughly every 15 °C of temperature rise above about 70 °C. Where speed, temperature or the required interval put grease out of reach, change to oil.

Sealed-for-life versions carry their whole service life of grease inside the seals and cannot be relubricated. That is the right choice where the bearing is inaccessible and the duty is mild; it is the wrong one where the temperature is high, the environment is wet, or the required life is longer than the grease life — and the grease, not the steel, is what ends it.

Where a 75 mm Bore 6000-ZZ Series Shielded Ball Bearings Is Used

At a 75 mm bore, 6000-zz series shielded ball bearings are typically found in industrial gearboxes, fans and blowers, conveyor drives, pump and compressor shafts and machine tool spindles, where the load and the heat generated both start to decide the arrangement.

Failure Modes and What They Look Like

  • Subsurface fatigue (spalling) — a flake of raceway lifts out and the bearing gets noisy and rough. This is the failure the L10 life calculation predicts — if it arrives near the calculated life the bearing did its job, and if it arrives early the load, the fit or the lubrication was not what the calculation assumed.
  • Inadequate lubrication — a polished, then discoloured, then torn raceway, running hot with a darkened grease. It is the most common cause of early failure by a wide margin, and the interval, not the grease, is usually what was wrong.
  • Contamination — dents in the raceway with raised edges, then premature spalling from those dents. Wear particles, casting sand and washdown water all do it; sealing and filtration are what prevent it.
  • False brinelling and fretting — evenly spaced dull marks at ball or roller pitch, produced by vibration while the shaft is stationary — a machine that travels on a truck, or a standby pump beside a running one. It is not caused by overload and cannot be cured by fitting a bigger bearing.
  • Loss of internal clearance — the whole raceway path is loaded, the bearing runs hot from installation and it discolours evenly. The fit was too heavy, the shaft ran hotter than the housing, or a CN bearing was fitted where C3 was needed.
  • Skidding under light load — smeared, matte patches on the raceway. A ball or thrust bearing that is not loaded enough to make its rolling elements roll lets them slide instead, and the film breaks down where they scuff.

Where NOT to Use a 6000-ZZ Series Shielded Ball Bearings

  • Do not use a deep groove ball bearing as a thrust bearing. Its axial capacity is a secondary property of the groove shoulders, and under pure heavy axial load the contact ellipse rides over the shoulder edge and the raceway breaks up there.
  • Do not use one where the shaft misaligns. A deep groove bearing tolerates only a few minutes of arc; beyond that it edge-loads. Use a self-aligning ball bearing, a spherical roller bearing or a housed unit instead.
  • Do not expect a 2RS bearing to survive a hot washdown. A standard nitrile contact seal is a lip running on steel, not a pressure seal: a 80 °C detergent wash drives past it and into the grease, and the bearing fails from water, not from load.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the designation snaps the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.
Our facility

Where these dimensions are actually made

Ring forging, heat treatment, raceway grinding and superfinishing all happen under one roof, so a bore tolerance and a clearance group are set by processes we control and can evidence, not by whichever supplier had stock.

Bearing production line, wide view
Ring inspection station
Bearing assembly and clearance setting
Finished bearings staged for packing

Request a Quote

The form below follows the current technical drawing configuration. Change the drawing values above and the request details update automatically.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ISO 15 / DIN 625-1 / GB/T 276)

DesignationBore d (mm)Outer diameter D (mm)Width B (mm)Chamfer r min (mm)Shield typeOperating temperature range (u00b0C)Basic dynamic load rating Cr (kN)Basic static load rating C0r (kN)
6000-ZZ102680.3Pressed steel shield, both sides-30 to +1204.751.96
6001-ZZ122880.3Pressed steel shield, both sides-30 to +1205.42.36
6002-ZZ153290.3Pressed steel shield, both sides-30 to +1205.852.85
6003-ZZ1735100.3Pressed steel shield, both sides-30 to +1206.053.25
6004-ZZ2042120.6Pressed steel shield, both sides-30 to +1209.955.0
6005-ZZ2547120.6Pressed steel shield, both sides-30 to +12011.96.55
6006-ZZ3055131Pressed steel shield, both sides-30 to +12013.88.3
6007-ZZ3562141Pressed steel shield, both sides-30 to +12016.810.2
6008-ZZ4068151Pressed steel shield, both sides-30 to +12017.811.6
6009-ZZ4575161Pressed steel shield, both sides-30 to +12022.114.6
6010-ZZ5080161Pressed steel shield, both sides-30 to +12022.916.0
6011-ZZ5590181.1Pressed steel shield, both sides-30 to +12030.721.2
6012-ZZ6095181.1Pressed steel shield, both sides-30 to +12030.723.2
6013-ZZ65100181.1Pressed steel shield, both sides-30 to +12032.525.0
6014-ZZ70110201.1Pressed steel shield, both sides-30 to +12039.731.0
6015-ZZ75115201.1Pressed steel shield, both sides-30 to +12041.633.5
6016-ZZ80125221.1Pressed steel shield, both sides-30 to +12047.539.0
6017-ZZ85130221.1Pressed steel shield, both sides-30 to +12049.441.5
6018-ZZ90140241.5Pressed steel shield, both sides-30 to +12060.550.0
6019-ZZ95145241.5Pressed steel shield, both sides-30 to +12063.754.0
6020-ZZ100150241.5Pressed steel shield, both sides-30 to +12060.554.0

Video: 75 mm Bore 6000-ZZ Series Shielded Ball Bearings Dimensions

Third-party video, selected automatically for this topic. It is not produced by Bushing Bearings and is not a specification source — use the tables on this page for dimensional data.

Frequently Asked Questions

What shaft tolerance should a 75 mm bearing seat be machined to?

For a rotating inner ring under a normal load on a solid steel shaft, k5 or k6 is the usual seat at this diameter; j6 under light load and n6 under heavy or shock load. Machine the housing to H7 where the outer ring has to be free to move axially, or J7 where it does not.

What is the internal clearance of a 75 mm bore bearing?

Before mounting, a CN (normal) bearing in this bore range has 10–30 µm of radial internal clearance and a C3 bearing has 25–51 µm, per ISO 5753-1. Part of that is consumed by the interference fit and by any temperature difference between the inner and outer ring.

Do I need C3 clearance or is CN enough?

CN is right for the ordinary case: a moderate interference fit on a shaft running close to housing temperature. Specify C3 when the fit is heavier than normal, when the inner ring will run 10 °C or more hotter than the outer, when the shaft is hollow or heated, or when the bearing is driven up an adapter sleeve. A CN bearing fitted tight on a hot shaft can lose all its clearance and preload itself.

What load can a 75 mm bore 6000-ZZ Series Shielded Ball Bearings carry?

The basic dynamic load rating Cr for this size is 41.6 kN, with a static rating C0r of 33.5 kN. That is not a working load: it is the load at which the bearing reaches one million revolutions of rating life, and the working load follows from the life you need — L10 = (C/P)^p, with p = 3 for ball bearings and 10/3 for roller bearings.

How do I request a quotation?

Use the technical drawing on this page to pick the exact configuration, then submit it with the quote form. We respond within one business day.